Applying hid high-pressure sodium lamps in a variable-voltage environment. J-. IEEE.
1995
SEPARATA
686
This paper present the results of laboratory test to determine the effects of voltage sags, interruptions and fluctuations on high-pressure sodium(HPS) lamps and ballast. The way these bailasted lamps react to sags and interruptions in the laboratory is then compared to a model of the real world electrical environment created from data gathered during three recent North American Power quality surveys. This work also shows how HPS immunity to voltage variations depends significantly on the ballast type and the lamp age..
Presenta gráfs
Ministerio de Ambiente y Energía. Secretaría de Planificación del Sub-Sector Energía - Centro de Información de Energía y Ambiente, CIENA
Grettel Ruiz Matarrita
Calle 25, Avenidas 8 y 10. San José, Costa Rica
(506)25476900 - 25476239
De lunes a viernes de 8 a.m. a 12m.