« Volver Ficha del Documento

A method of using IN SITU porosity measurements to place an upper bound on geothermal reservoir compaction. En : Second invitational well - testing symposium.

1978

621.44
L4191

Placing an upper bound on reservoir compaction requires placing a lover bound an the reservoir effective compaction modulus. Porosity-depth data can be used to find the lower-bound modulus in a young sedimetary basin. Well-log and sample porosity data from a geothermal field in the Imperial Valley, CA, give a lower-bound modulus of 7.7 X 10º psi.