« Volver Ficha del Documento

Tratamiento de efluentes de una industria textil del cantón Pelileo, Provincia de Tungurahua, contaminados con colorantes azoicos, mediante un proceso electro-fenton

2014-07-28

Balladares Moyano, O. D. (2014). Tratamiento de efluentes de una industria textil del cantón Pelileo, Provincia de Tungurahua, contaminados con colorantes azoicos, mediante un proceso electro-fenton. Quito: EPN.
T-IQ/0904/CD-ROM 5669

153 hojas : ilustraciones, 29 x 21 cm + CD 5669

Se estudió el tratamiento de los efluentes de una empresa textil del cantón Pelileo, mediante un proceso electro-Fenton para eliminar los colorantes azoicos. Para ello, se trataron primero, soluciones sintéticas de los colorantes azul BRL, pardo LEGL y la combinación de ellos en el sistema electro-Fenton a 8 A y 10 A de corriente eléctrica. Se trabajó a condiciones fijas de pH (3,0), concentración de sulfato ferroso (0,56 mmol∙L-1) y distancia entre electrodos (0,5 cm) y se determinó que la corriente eléctrica que permitió obtener los mejores resultados fue 10 A. Se trató el efluente en modalidad batch y se determinó un tiempo de residencia de 9 min, que permitió disminuir el valor de los parámetros en estudio: DQO, color y turbidez, a valores dentro de la norma TULSMA. Finalmente, se trató el efluente en modalidad continua con tres diferentes flujos (60, 70 y 85 mL∙min-1), Se estableció que el flujo de 70 mL∙min-1 permitió alcanzar la mayor disminución de la DQO. Se diseñó un proceso electro-Fenton, el costo total fue de 164 178,40 USD. El costo operativo del sistema electro-Fenton en función del volumen tratado fue de 14,39 USD/m3.- ABSTRACT.- An electro-fenton treatment of effluents from a textile company in the canton Pelileo was studied to remove azo dyes. For this purpose, initially, synthetic dyes solutions of BRL blue, brown LEGL and the combination of them in the electro-Fenton system at 8 A and 10 A of current were treated. The experiments were carried out at fixed pH conditions (3.0), ferrous sulfate concentration (0.56 mmol L-1) and electrode distance (0.5 cm) and it was established the electric current that yielded the best results, which was 10 A. The effluent was treated in batch mode and it was determined that a residence time of 9 min allowed a reduction of the studied parameters: COD, color and turbidity values within the TULSMA standard. Finally, the effluent in continuous mode with three different flows (60, 70 and 85 mL min-1) was treated and a flow of 70 mL min-1 was established as the condition to achieve the best reduction in COD. An electro-Fenton process was designed, and a total cost of 164 178,40 was calculated. The operative cost of an electro-Fenton system based on the treated volume was 14,39 USD/m3.

Muñoz Bisesti, Florinella, director

Escuela Politécnica Nacional - Biblioteca Central

Olga de Beltrán

Ladrón de Guevara E11-253 y Andalucía.


Dirección: Av. Mariscal Antonio José de Sucre N58-63 y Fernández Salvador Edif. Olade - San Carlos, Quito - Ecuador.

Web: www.olade.org

Teléfonos: (593 2) 259 8122 / 2598 280

Correo: realc@olade.org

ADMIN
Desarrollado por: Aikyu-Systems