Development of NO3 - N Analyser for Real-Time Nitrate Control in a Pilot Urban Wastewater Treatment Plant

2007-03-21T16:12:42Z

This paper reports on the design and con- struction of a prototype for the measurement of Nitrate-Nitrogen (NO− − N) concentration in urban wastewater for real-time nitrate control in treatment plants. The system acquires the sample in an automatic mode and performs the measurement using an ion selective electrode (ISE). Additionaly the equipment has a friendly user interface and can exchange data with a supervisory system, using the MODBUS protocol over a RS-485 interface.

Escuela Politécnica Nacional - Biblioteca Central

Olga de Beltrán

Ladrón de Guevara E11-253 y Andalucía.


Dirección: Av. Mariscal Antonio José de Sucre N58-63 y Fernández Salvador Edif. Olade - San Carlos, Quito - Ecuador.

Web: www.olade.org

Teléfonos: (593 2) 259 8122 / 2598 280

Correo: realc@olade.org